Curtain Fire Dampers

UL 555 rated models with either Galvanized or 304 Stainless Steel construction. Fire resistance ratings of either 1 1/2 or 3 hours.

Model FD: Static Rated

UL 555 rated models for use in HVAC systems that are automatically shut down in the event of a fire emergency. Available in three frame widths, standard, narrowline, and ultra thin, with optional sleeves and transitions.

Model DFD: Dynamic Rated

UL 555 rated models tested to close under airflow, and rated for use in HVAC systems that are operational in the event of a fire emergency. Fire dampers can be mounted either vertically or horizontally with airflow in either direction.

Downloadable Greenheck Literature
Only titles in red are currently active - Viewable with the Adobe Acrobat Reader
(Click here for more information or to download the Acrobat reader)

Catalogs:
Dynamic and Static Rated Fire Dampers (360k)
Selection and Application Manuals:
Dynamic Rated Fire Dampers (62k)
Installation Instructions:
Standard FD and DFD Curtain Fire Dampers (78k)
FD and DFD Curtain Fire Dampers with Integral Sleeves (91k)
FD and DFD Curtain Fire Dampers with Integral Sleeves Mounted in Steel Stud Walls (81k)
Specification Sheets:
Static Rated:
Round Transitions, Type R (30k)
1 1/2 Hour, Standard Frame (FD-150A) (35k)
1 1/2 Hour, Standard Frame (FD-150B) (36k)
1 1/2 Hour, Standard Frame (FD-150R) (31k)
1 1/2 Hour, Standard Frame (FD-150CR-C-CO) (37k)
1 1/2 Hour, 20 Ga. Integral Sleeve (FD-150XA) (34k)
1 1/2 Hour, 20 Ga. Integral Sleeve (FD-150XB) (34k)
1 1/2 Hour, 20 Ga. Integral Sleeve (FD-150XCR-C-CO) (37k)
1 1/2 Hour, 20 Ga. Integral Sleeve (FD-150XR) (26k)
1 1/2 Hour, Standard Frame, Sealed (FD-155CR-C-CO) (37k)
1 1/2 Hour, Standard Frame, 304SS (SSFD-150) (28k)
1 1/2 Hour, Standard Frame, 304SS, Sealed (SSFD-155) (28k)
1 1/2 Hour, Narrowline Frame, 2 3/16" Depth (FD-110A-B) (24k)
1 1/2 Hour, Ultrathin Frame, 1 1/2" Depth (FD-100A-B) (22k)
3 Hour, Standard Frame (FD-350A-B) (27k)
3 Hour, Standard Frame (FD-350CR-C-CO) (32k)
3 Hour, Standard Frame, Sealed (FD-355CR-C-CO) (32k)
3 Hour, Standard Frame, 304SS (SSFD-350) (28k)
3 Hour, Standard Frame, 304SS, Sealed (SSFD-355) (28k)
3 Hour, Narrowline Frame, 2 3/16" Depth (FD-310A-B) (22k)
3 Hour, Ultrathin Frame, 1 1/2" Depth (FD-300A-B) (22k)
Dynamic Rated:
1 1/2 Hour, Standard Frame (DFD-150A) (48k)
1 1/2 Hour, Standard Frame (DFD-150B) (49k)
1 1/2 Hour, Standard Frame (DFD-150R) (40k)
1 1/2 Hour, Standard Frame (DFD-150CR-C-CO) (68k)
1 1/2 Hour, 20 Ga. Integral Sleeve (DFD-150XA) (51k)
1 1/2 Hour, 20 Ga. Integral Sleeve (DFD-150XB) (28k)
1 1/2 Hour, 20 Ga. Integral Sleeve (DFD-150XCR-C-CO) (49k)
1 1/2 Hour, 20 Ga. Integral Sleeve (DFD-150XR) (28k)
1 1/2 Hour, Standard Frame, Sealed (DFD-155CR-C-CO) (63k)
1 1/2 Hour, Standard Frame, 304SS (SSDFD-150) (28k)
1 1/2 Hour, Standard Frame, 304SS, Sealed (SSDFD-155) (28k)
1 1/2 Hour, Narrowline Frame, 2 3/16" Depth (DFD-110A-B) (34k)
3 Hour, Standard Frame, (DFD-350A-B) (34k)
3 Hour, Standard Frame (DFD-350CR-C-CO) (38k)
3 Hour, Standard Frame, (DFD-355CR-C-CO) (34k)
3 Hour, Standard Frame, 304SS (SSDFD-350) (28k)
3 Hour, Standard Frame, 304SS, Sealed (SSDFD-355) (28k)
3 Hour, Narrowline Frame, 2 3/16" Depth (DFD-310A-B) (28k)

Greenheck - P.O. Box 410, Schofield, WI 54476-0410, (715) 359-6171
© 1998, 1999 Greenheck